- Capacity:500 VA / 300 W
- Type:Line interactive
- Input voltage range:145 - 295 V ± 5 V
- Transfer time:2 - 4 ms
- Output sockets:4 × IEC320 C13, backup + filtering
- Battery:12 V 4.5 Ah × 1 pc, sealed lead acid
- Backup time at 50% load:4.50 min (estimated)
- Dimensions (D × W × H):100 × 280 × 140 mm
Crown Micro - CMU series line interactive UPS
CMU-500X IEC 500VA UPS 300 W with 4 IEC C13 outlets
The CMU-500X IEC is a compact line interactive UPS that protects a PC and its peripherals from mains interference and short outages. It tolerates a wide input voltage window and backs up four IEC C13 outlets from a sealed internal battery. It suits desktop and small office setups where the mains is not always stable.
- 500 VA / 300 W
- Boost and buck AVR
- Cold start
- 4 IEC C13 outlets
- 2-4 ms transfer
- 500 VA
- Capacity (300 W)
- 145-295 V
- Input voltage range
- 2-4 ms
- Transfer time
- 4 IEC C13
- Backed-up outlets
The Crown Micro CMU-500X IEC 500 VA line interactive UPS delivers 500 VA / 300 W and accepts mains from 145 to 295 V. Boost and buck automatic voltage regulation keeps the mains output at 220 / 230 V ± 10% without using the battery, and the unit switches to battery in 2 to 4 ms when the supply fails.
Four IEC320 C13 outlets provide backup and filtering for a computer and its peripherals. A sealed, maintenance-free 12 V 4.5 Ah lead acid battery supplies the backup, and the UPS can start on battery without mains and restart by itself when mains power returns.
Technology features
- RegulationBoost and buck AVR Automatic voltage regulation across the 145 - 295 V input range keeps the mains output at 220 / 230 V ± 10%.
- ControlDigital control Microprocessor-based control with automatic frequency sensing and a power-on self test.
- Battery careSmart battery management Three-stage charging with temperature compensation, plus automatic charging while the UPS is in OFF mode.
- SafetyFull protection Short-circuit, overload, surge and battery overcharge / overdischarge protection are built in.
- AvailabilityCold start and auto restart The CMU-500X IEC starts on battery without mains and restarts automatically when mains power is restored.
- FeedbackLED and sound alarm Green, yellow and red LEDs show mains, battery mode and fault, backed by audible alarms.
Operating states
Technical specifications
| Model | CMU-500X IEC |
|---|---|
| Type | Line interactive |
| Capacity | 500 VA / 300 W |
| Input voltage | 220 / 230 / 240 V |
| Input voltage range | 145 - 295 V ± 5 V |
| AC input frequency | 50 / 60 Hz ± 1 Hz |
| Power cord | Built-in, EURO plug (1.5 m) |
| Voltage (mains) | 220 / 230 V ± 10% |
|---|---|
| Frequency (mains) | 50 / 60 Hz ± 1 Hz |
| Voltage (battery) | 220 / 230 V ± 5% (square wave) |
| Frequency (battery) | 50 / 60 Hz ± 1 Hz (auto adjusted) |
| Transfer time | 2 - 4 ms |
| Output sockets | 4 × IEC320 C13, backup + filtering |
| LAN / telephone protection | No |
| PC monitoring and control | No |
| Battery type | Lead acid, sealed, maintenance free |
|---|---|
| Voltage and capacity | 12 V 4.5 Ah × 1 pc |
| Backup time at 50% load * | 4.50 min |
| Backup time at 100% load * | 1.40 min |
| Charge time | About 4 hours |
| Battery protection | Automatic shutdown when the battery is low |
|---|---|
| Short circuit | Output shuts off automatically, continuous alarm |
| Overload | 110 - 120%: frequent beep; above 120%: output shuts off, continuous alarm |
| LED indication | Green: mains; yellow: battery mode; red: overload or fault |
| Sound alarm | Standby: 1 beep every 5 s, then every 60 s; low battery: frequent beep (last 16 s); overload: beep every 2 s |
| Case material | Plastic |
|---|---|
| Dimensions (D × W × H) | 100 × 280 × 140 mm |
| Weight | 3.6 kg |
| Operating temperature | 0 °C to 40 °C |
| Storage temperature | -15 °C to 45 °C |
| Relative humidity | 0 - 90% (non-condensing) |
| Noise level | ≤ 35 dB (at 1 m) |
* Estimated values; actual backup time depends on load and battery condition.
Integration segments
- Home desktop computers Keeps a PC running through short outages and filters mains disturbances.
- Home office peripherals Four backed-up IEC C13 outlets supply a computer together with its peripherals.
- Small office workstations Gives individual workstations time to save work and shut down safely.
- Sites with unstable mains The 145 - 295 V input window and AVR correct low and high voltage without switching to battery.
Global backing
Crown Micro: energy engineering with global backing.
- More than 30 years of international experience in energy solutions
- Commercial presence in more than 15 countries on four continents
- Product lines with international certifications
- Specialized technical support and after-sales engineering
- Personalized commercial advice for residential and productive projects
- Catalog covering inverters, lithium batteries, frequency drives, panels and kits
Preguntas frecuentes
What load can the CMU-500X IEC support?
The CMU-500X IEC is rated at 500 VA / 300 W. Keep the combined load of the connected devices within 300 W. Between 110 and 120% load the UPS beeps frequently, and above 120% the output shuts off with a continuous alarm.
How long does the CMU-500X IEC run on battery?
The datasheet gives estimated backup of 4.50 min at 50% load and 1.40 min at 100% load. These are estimates, and actual time depends on the load and the condition of the battery.
What input voltage range does it accept?
The input range is 145 - 295 V ± 5 V, for nominal inputs of 220 / 230 / 240 V at 50 / 60 Hz ± 1 Hz. Boost and buck AVR regulates the mains output to 220 / 230 V ± 10% within that range.
What kind of output does it give on battery?
In battery mode the output is a square wave of 220 / 230 V ± 5% at 50 / 60 Hz ± 1 Hz, with the frequency adjusted automatically. The transfer from mains to battery takes 2 to 4 ms.
Does the CMU-500X IEC have PC communication or LAN protection?
No. The datasheet lists PC monitoring and control as No, and LAN / telephone protection as No. Status is shown by the green, yellow and red LEDs and by audible alarms.
Does the battery need maintenance, and how long does it take to charge?
The battery is a sealed, maintenance-free lead acid 12 V 4.5 Ah unit. Charging takes about 4 hours, using three-stage charging with temperature compensation, and the UPS also charges automatically in OFF mode.
Can the UPS start without mains power?
Yes, the CMU-500X IEC has a cold start function that lets it start on battery without mains. It also restarts automatically when mains power is restored.