Crown Micro CMU-SP1200 IEC USB 1200VA Line Interactive UPS
SKU: CMU-SP1200IEC-USB
Line interactive UPS of 1200 VA / 720 W with boost and buck AVR, a 140-290 V input range, 8 + 1 IEC C13 outlets, RJ-11/45 line protection and USB monitoring.
Cuéntanos tu proyecto y te recomendamos el equipo adecuado.
Hablar con un asesorCaracterísticas destacadas
Garantía oficial: 1 año
- Capacity:1200 VA / 720 W
- Input voltage range:140 - 290 V ± 5 V
- Transfer time:2 - 4 ms
- Output connectors:8 × IEC320 C13 (backup + filter) + 1 × IEC320 C13 bypass
- Battery:12 V 9 Ah × 2
- Backup at 50% load:16.30 min (estimated)
- Monitoring:USB port
- Net weight:10.2 kg
Crown Micro - CMU-SP series line interactive UPS
CMU-SP1200 IEC USB UPS 1200 VA / 720 W
The CMU-SP1200 IEC USB is a line interactive UPS that shields PCs and peripherals from mains disturbances and short outages. It combines boost and buck voltage regulation, eight backed-up IEC C13 outlets and USB monitoring in a compact desktop unit.
- 1200 VA / 720 W
- 8 + 1 IEC C13 outlets
- Boost and buck AVR
- USB monitoring
- Cold start
- 1,200 VA
- Capacity (720 W)
- 140-290 V
- Input voltage range
- 2-4 ms
- Transfer time
- 16.3 min
- Backup at 50% load
The Crown Micro CMU-SP1200 IEC USB line interactive UPS delivers 1200 VA / 720 W and keeps connected equipment running through a 140-290 V input range thanks to boost and buck automatic voltage regulation. On mains, the output stays at 220 / 230 V ± 10%, and the transfer to battery takes 2 to 4 ms.
Eight IEC320 C13 outlets provide battery backup and filtering, and a ninth C13 outlet works as a bypass outlet. A USB port lets a PC monitor and control the unit, and an RJ-11/45 port protects telephone, fax, modem and LAN lines. Two 12 V 9 Ah sealed lead acid batteries supply about 16.3 minutes at 50% load (estimated value).
Technology features
- RegulationBoost and buck AVR Automatic voltage regulation keeps the mains output at 220 / 230 V ± 10% across the wide input range.
- Outlets8 + 1 IEC C13 sockets Eight IEC320 C13 sockets carry backup power and filtering, and one more C13 socket serves as a bypass outlet.
- ProtectionFull protection Short-circuit, overload, surge and battery overcharge and over-discharge protections safeguard the UPS and the load.
- Data linesPhone and LAN protection One RJ-11/45 port protects telephone, fax, modem and Internet lines.
- MonitoringUSB management The USB port allows monitoring and control from a PC, including unattended safety shutdown.
- AvailabilityCold start and auto restart The UPS can start on battery without mains and restarts automatically when mains power returns.
Status indication
Intelligent control and battery care
- ControlMicroprocessor-based digital control Digital control includes a power-on self test, auto sensing of the input frequency and a selectable LED or LCD display.
- SynchronizationMains phase tracking The inverter output follows the phase of the utility voltage, which reduces transfer time and peak surge.
- BatteryIntelligent battery management Battery temperature compensation helps extend battery life, and three-stage charging shortens recharge time.
Technical specifications
| Model | CMU-SP1200 IEC USB |
|---|---|
| Type of UPS | Line interactive |
| Capacity | 1200 VA / 720 W |
| Input voltage | 220 / 230 / 240 V |
| Input voltage range | 140 - 290 V ± 5 V |
| Input frequency | 50 / 60 Hz ± 1 Hz |
| Power cord | Removable, EURO plug (1.8 m) |
| Voltage (mains) | 220 / 230 V ± 10% |
|---|---|
| Voltage (battery) | 220 / 230 V ± 5% (square wave) |
| Frequency | 50 / 60 Hz ± 1 Hz (auto adjusted) |
| Transfer time | 2 - 4 ms |
| AVR | Boost and buck |
| Output connectors | 8 × IEC320 C13 (backup + filter) |
| Bypass outlet | 1 × IEC320 C13 |
| Type | Sealed lead acid, maintenance free |
|---|---|
| Voltage and capacity | 12 V 9 Ah × 2 |
| Typical recharge time | About 8 hours |
| Backup at 50% load * | 16.30 min |
| Backup at 100% load * | 2.50 min |
| Cold start | Yes |
| Battery protection | Auto shutdown on low battery |
| Overload | 110 - 120%: frequent beep; > 120%: output shuts off, continuous alarm |
|---|---|
| Short circuit | Output shuts off automatically, continuous alarm |
| Phone, fax, modem, LAN | 1 × RJ-11/45 |
| PC monitoring and control | USB port |
| Indication | LED: green mains, yellow battery mode, red overload or fault |
| Sound alarm | Standby: 1 beep every 5 s, then every 60 s; low charge: frequent beep (last 16 s); overload: beep every 2 s |
| Dimensions (D × W × H) | 125 × 320 × 225 mm |
|---|---|
| Net weight | 10.2 kg |
| Acoustic noise | < 35 dB (at 1 m) |
| Operating temperature | 0 °C to 40 °C |
| Storage temperature | -15 °C to 45 °C |
| Relative humidity | 0 - 90% (non-condensing) |
* Estimated value; actual backup time depends on load and battery condition.
Integration segments
- Home office computers Backup and filtering for a desktop PC and its peripherals against mains interference and short outages.
- Small office workstations Eight backed-up outlets let several devices share one UPS, with a bypass outlet for equipment that does not need backup.
- Network and communication equipment The RJ-11/45 port protects telephone, fax, modem and LAN lines alongside the powered equipment.
- Unattended PC systems USB communication enables monitoring and unattended safety shutdown of a connected PC during an outage.
Global backing
Crown Micro: energy engineering with global backing.
- More than 30 years of international experience in energy solutions
- Commercial presence in more than 15 countries on four continents
- Product lines with international certifications
- Specialized technical support and after-sales engineering
- Personalized commercial advice for residential and productive projects
- Solutions that range from UPS units to inverters, lithium batteries and solar kits
Preguntas frecuentes
How many devices can be connected to the CMU-SP1200 IEC USB?
The UPS has eight IEC320 C13 outlets with battery backup and filtering, plus one IEC320 C13 bypass outlet. The total capacity is 1200 VA / 720 W, so the combined load must stay within that limit.
How long does the CMU-SP1200 IEC USB run on battery?
The datasheet gives about 16.3 minutes at 50% load and 2.5 minutes at 100% load, using the two 12 V 9 Ah batteries. These are estimated values, and the actual time depends on the load and battery condition.
What is the output waveform on battery?
On battery, the output is 220 / 230 V ± 5% with a square wave. On mains, the output is 220 / 230 V ± 10% with boost and buck AVR regulation.
What input voltage range does the UPS accept?
The input range is 140 - 290 V ± 5 V at a nominal 220 / 230 / 240 V and 50 / 60 Hz ± 1 Hz. The boost and buck AVR corrects the voltage without using the battery.
Can the UPS start without mains power?
Yes, the CMU-SP1200 IEC USB supports cold start, so it can start on battery when no mains is present. It also restarts automatically when mains power is restored.
How is the UPS monitored from a PC?
A USB port connects the UPS to a PC for monitoring and control. This enables unattended safety shutdown, with a system alarm and automatic power on and off through the PC interface.
How long does the battery take to recharge?
The typical recharge time is about 8 hours. The UPS uses three-stage charging to shorten recharge time and battery temperature compensation to extend battery life.