Saltar al contenido
Crown Micro Xavier 2400VA 24V MPPT Simulated Sine Wave Inverter

Crown Micro Xavier 2400VA 24V MPPT Simulated Sine Wave Inverter

SKU: XAVIER-SWO-2400VA-1600W

The Xavier 2400VA is an off-grid inverter of 2400 VA / 1600 W for 24 VDC batteries, with a built-in 60 A MPPT charger for up to 1440 W of panels and a 4-year warranty.

Cuéntanos tu proyecto y te recomendamos el equipo adecuado.

Hablar con un asesor

Características destacadas

Garantía oficial: 4 años

  • Rated power:2400 VA / 1600 W
  • Battery voltage:24 VDC
  • Solar charger:60 A MPPT
  • Max. PV array power:1440 W
  • MPPT range:30 - 80 VDC
  • AC input range:90 - 280 VAC or 170 - 280 VAC
  • Transfer time:20 ms
  • Peak efficiency:85%

Crown Micro - Xavier off-grid solar inverters

Xavier 2400VA 24V MPPT inverter 2400 VA / 1600 W with 60 A MPPT

The Xavier 2400VA is an off-grid solar inverter with a simulated sine wave output, built for a 24 VDC battery bank. It joins the inverter, a 60 A MPPT solar charger and an AC charger in one unit, for installers and buyers who need a compact backup and solar power solution.

  • 2400 VA / 1600 W
  • 60 A MPPT charger
  • 24 VDC battery
  • 1440 W PV input
  • 4-year warranty
2400 VA
Rated power
1440 W
Max. PV array power
60 A
MPPT solar charger
85 %
Peak efficiency

The Xavier 2400VA 24V MPPT simulated sine wave inverter (model X-2.4KVA-M) delivers 2400 VA / 1600 W from a 24 VDC battery and includes a built-in 60 A MPPT solar charger that accepts up to 1440 W of solar panels.

The inverter accepts a wide AC input range of 90 to 280 VAC, transfers to the battery in 20 ms and lets the user choose the output source priority from the LCD. An AC charger of 10 A or 25 A, a coated PCB and a built-in anti-dust kit complete the design for off-grid and backup systems.

Technology features

  • Solar charging60 A MPPT charger Handles up to 1440 W of panels with an MPPT range of 30 to 80 VDC and a maximum open-circuit voltage of 100 VDC.
  • OutputSimulated sine wave Battery mode output is 230 VAC ± 10%, with 85% peak efficiency and a 20 ms transfer time.
  • ControlSelectable output priority The output source priority is chosen through the LCD settings, and the input window can be set to 90 - 280 VAC or 170 - 280 VAC.
  • ChargingSolar and AC charging Total charge current reaches 60 A, either from solar or from the AC grid at 10 A or 25 A.
  • ProtectionOverload and short-circuit safeguards Overload, short-circuit, overcharge and thermal protection sensor guard the inverter and the battery.
  • Interface and buildLCD, RGB light bar and coating The LCD/LED display shows system information, an RGB light bar signals status, and the PCB is coated against the environment with a built-in anti-dust kit.

Technical specifications

General and input
Model nameXavier-2400VA-MPPT
Model numberX-2.4KVA-M
Rated power2400 VA / 1600 W
Input voltage230 VAC
Selectable voltage range90 - 280 VAC or 170 - 280 VAC
Frequency range50 / 60 Hz (auto sensing)
Output
AC voltage regulation (battery mode)230 VAC ± 10%
Peak efficiency85%
Transfer time20 ms
WaveformSimulated sine wave
Overload capability
Load above 110% ± 15%Alarm for 5 minutes, then inverter fault; the alarm releases if the load drops below 100%
Load above 130% ± 15%Inverter fault immediately
Battery
Battery voltage24 VDC
Floating charge voltage27.4 VDC ± 1 VDC
Overcharge protection30.0 VDC ± 0.5 VDC
Solar charger and AC charger
Solar charger typeMPPT
Max. PV array open-circuit voltage100 VDC
Max. PV array power1440 W
MPPT range at operating voltage30 - 80 VDC
Max. solar charge current60 A
Max. AC charge current10 A / 25 A
Max. charge current60 A
Operating environment
Humidity0 - 90% RH (non-condensing)
Operating temperature0 °C to 40 °C
Storage temperature-15 °C to 55 °C

Integration segments

  1. Off-grid homes and cabins A 24 V solar system with a built-in MPPT charger for households without a stable grid connection.
  2. Backup for unstable grids The 20 ms transfer time and wide 90 - 280 VAC input window keep loads running through grid variations.
  3. Small solar installations Up to 1440 W of panels can feed the battery bank directly through the 60 A MPPT charger.
  4. Light residential and productive loads 1600 W of output covers lighting, electronics and other equipment suited to a simulated sine wave supply.
4
Years

Crown Micro warranty and support The official warranty is 4 years: 1 year of comprehensive warranty plus 3 years of free services. Manufacturer terms apply.

Compact 24 V solar power with built-in MPPT

The Xavier 2400VA brings 1600 W of output, a 60 A MPPT charger and selectable output priority into one unit. It suits 24 V off-grid and backup systems that need straightforward control.

Crown Micro - A trusted global brand

Global backing

Crown Micro: energy engineering with global backing.

  • More than 30 years of international experience in energy solutions
  • Commercial presence in more than 15 countries on four continents
  • Product lines with international certifications
  • Specialized technical support and after-sales engineering
  • Personalized commercial advice for residential and productive projects
  • 4-year warranty: 1 year comprehensive plus 3 years of free services

Preguntas frecuentes

What battery voltage does the Xavier 2400VA use?

The Xavier 2400VA works with a 24 VDC battery. The floating charge voltage is 27.4 VDC ± 1 VDC and overcharge protection acts at 30.0 VDC ± 0.5 VDC.

How many solar panels can be connected?

The built-in MPPT charger accepts a PV array of up to 1440 W. The maximum open-circuit voltage is 100 VDC and the MPPT operating range is 30 to 80 VDC.

What is the maximum charge current?

The total maximum charge current is 60 A. It can come from solar at up to 60 A or from the AC grid at 10 A or 25 A.

What type of output waveform does the inverter produce?

The Xavier 2400VA produces a simulated sine wave output, with 230 VAC ± 10% regulation in battery mode. Peak efficiency is 85%.

How does the inverter handle overloads?

With a load above 110% ± 15%, it sounds an alarm for 5 minutes and then goes into inverter fault; the alarm releases if the load drops below 100%. Above 130% ± 15% the inverter faults immediately.

Can the output source priority be changed?

Yes. The output source priority is selected through the LCD settings. The AC input range can be set to 90 - 280 VAC or 170 - 280 VAC.

What warranty does the Xavier 2400VA include?

The official warranty is 4 years, made up of 1 year of comprehensive warranty plus 3 years of free services. Manufacturer terms apply.