Crown Micro Xavier II 4KW 24V 120A MPPT Hybrid Inverter
SKU: XAVIER-4KW
The Xavier II 4KW is a 4000 VA / 4000 W pure sine wave hybrid inverter with a 120 A MPPT charger, 5000 W PV input, 24 VDC battery, built-in BMS port and Wi-Fi.
Cuéntanos tu proyecto y te recomendamos el equipo adecuado.
Hablar con un asesorCaracterísticas destacadas
Garantía oficial: 4 años
- Rated power:4000 VA / 4000 W
- Surge power:8000 VA
- Battery voltage:24 VDC
- Max. PV array power:5000 W
- MPPT range:60 to 450 VDC
- Max. solar charge current:120 A
- Peak efficiency:93%
- Communication:Wi-Fi / RS-485 / CAN
Crown Micro - Xavier II series
Xavier II 4KW Hybrid Inverter 120 A MPPT charger
The Xavier II 4KW is a hybrid solar inverter with a built-in MPPT charger and pure sine wave output. It runs from a 24 VDC battery and accepts utility grid or generator input. It suits installers who need a compact 4000 W unit with remote monitoring and battery communication.
- 4000 W pure sine wave
- 120 A MPPT charger
- 24 V battery
- Built-in BMS port
- Built-in Wi-Fi
- 4000 W
- Rated power
- 5000 W
- Max. PV array power
- 120 A
- Max. solar charge
- 93 %
- Peak efficiency
The Xavier II 4KW hybrid inverter delivers 4000 VA / 4000 W of pure sine wave power at 230 VAC, with an 8000 VA surge capacity. Its built-in MPPT solar charger accepts up to 5000 W of panels and supplies up to 120 A of solar charge current to a 24 VDC battery.
The inverter works with utility grid or generator input, offers dual outputs for priority and normal loads, and has a battery-independent design. Built-in Wi-Fi supports remote monitoring, while RS-485 and CAN ports handle communication with a lithium battery BMS.
Technology features
- Solar charging120 A MPPT charger Accepts up to 5000 W of panels across a 60 to 450 VDC MPPT range, with PV input current up to 27 A.
- OutputPure sine wave 230 VAC output with power factor 1, 8000 VA surge power and 93% peak efficiency.
- Load managementDual outputs Integrated dual outputs separate priority loads from normal loads for smarter use of stored energy.
- Battery careEqualization and BMS The battery-independent design, built-in BMS and equalization function help optimize battery performance and extend its lifecycle.
- InterfaceLCD touch pad An LCD with touch pad and RGB lighting on the Crown logo gives local control and status on the front panel.
- ConnectivityWi-Fi, RS-485 and CAN Built-in Wi-Fi enables remote monitoring, and the RS-485 and CAN ports communicate with lithium battery BMS.
Technical specifications
| Model | XAVIER II 4KW |
|---|---|
| Rated power | 4000 VA / 4000 W |
| Surge power | 8000 VA |
| Input voltage | 230 VAC |
| Range for personal computers | 170 to 280 VAC |
| Range for home appliances | 90 to 280 VAC |
| Frequency range | 50 / 60 Hz (auto sensing) |
| AC voltage regulation (battery mode) | 230 VAC ± 5% |
| Peak efficiency | 93% |
| Transfer time (personal computers) | 10 ms |
| Transfer time (home appliances) | 20 ms |
| Waveform | Pure sine wave |
| Dual outputs | Yes |
| Battery voltage | 24 VDC |
|---|---|
| Floating charge voltage | 27 VDC |
| Overcharge protection | 33 VDC |
| Max. charge current | 120 A |
| Solar charger type | MPPT |
|---|---|
| Max. PV array power | 5000 W |
| Max. PV array open-circuit voltage | 500 VDC |
| MPPT range at operating voltage | 60 to 450 VDC |
| Max. PV input current | 27 A |
| Max. solar charge current | 120 A |
| Max. AC charge current | 100 A |
| Dimensions (D × W × H) | 107 × 322.6 × 420.3 mm |
|---|---|
| Net weight | 9.5 kg |
| Communication | Wi-Fi / RS-485 / CAN |
| Humidity | 5 to 95% (non-condensing) |
| Operating temperature | -10 °C to 50 °C |
| Storage temperature | -15 °C to 60 °C |
Integration segments
- Off-grid homes and cabins A 4000 W pure sine wave source with MPPT solar charging for households that rely on a 24 VDC battery bank.
- Homes with grid or generator support Utility grid or generator input can charge the battery at up to 100 A when solar energy is not enough.
- Small commercial and productive loads Dual outputs let priority equipment stay powered while normal loads are managed separately.
- Lithium battery systems with monitoring RS-485 and CAN ports communicate with lithium battery BMS, and built-in Wi-Fi supports remote monitoring.
Global backing
Crown Micro: energy engineering with global backing.
- More than 30 years of international experience in energy solutions
- Commercial presence in more than 15 countries on four continents
- Product lines with international certifications
- Specialized technical support and after-sales engineering
- Personalized commercial advice for residential and productive projects
Preguntas frecuentes
What battery voltage does the Xavier II 4KW use?
The Xavier II 4KW works with a 24 VDC battery. Its floating charge voltage is 27 VDC and overcharge protection is set at 33 VDC.
How much solar power can be connected to the Xavier II 4KW?
The built-in MPPT charger accepts up to 5000 W of PV array power. The MPPT range is 60 to 450 VDC, maximum PV input current is 27 A and open-circuit voltage must not exceed 500 VDC.
What is the maximum charge current?
Solar charging reaches up to 120 A and AC charging reaches up to 100 A, from grid or generator. The maximum total charge current is 120 A.
Can the Xavier II 4KW communicate with a lithium battery?
Yes. The inverter has RS-485 and CAN communication ports for lithium battery BMS. It also includes built-in Wi-Fi for remote monitoring.
Does the inverter work with a generator?
Yes. The Xavier II 4KW is compatible with utility grid or generator input at 230 VAC and 50 / 60 Hz with auto sensing. The AC input range can be selected by load type: personal computers or home appliances.
What is the transfer time and surge capacity?
Transfer time is 10 ms for the personal computers range and 20 ms for the home appliances range. Surge power is 8000 VA, against a rated power of 4000 VA / 4000 W.
What are the size, weight and operating temperature of the Xavier II 4KW?
The inverter measures 107 × 322.6 × 420.3 mm (D × W × H) and has a net weight of 9.5 kg. Operating temperature is -10 °C to 50 °C and humidity must be 5 to 95% non-condensing.