Saltar al contenido
Crown Micro CMUX CMU-850D 850 VA 480 W Offline Line Interactive UPS

Crown Micro CMUX CMU-850D 850 VA 480 W Offline Line Interactive UPS

SKU: CMU-850D

The CMU-850D is an 850 VA / 480 W offline line interactive UPS with boost and buck AVR, cold start, automatic restart and a 12 V 9 Ah battery, in a metal case.

Cuéntanos tu proyecto y te recomendamos el equipo adecuado.

Hablar con un asesor

Características destacadas

Garantía oficial: 1 año

  • Rated power:850 VA / 480 W
  • Type:Offline line interactive
  • Input voltage range (220 / 230 / 240 Vac):162 - 295 / 145 - 295 Vac
  • Switching time:8 ms typical, 10 ms max.
  • Waveform (mains / battery):Pure sine wave / simulated sine wave
  • Battery:12 V / 9 Ah x 1
  • Recharge time:6 - 8 h
  • Operating temperature:0 °C to 40 °C

Crown Micro - CMUX series offline line interactive UPS

CMU-850D 850 VA UPS 480 W offline line interactive

The CMU-850D is an offline line interactive UPS in a metal case, built to keep small electronic loads running through outages and unstable mains. Boost and buck AVR corrects voltage swings, and a 12 V 9 Ah battery takes over when the mains fails.

  • 850 VA / 480 W
  • Boost and buck AVR
  • Cold start
  • Auto restart
  • 12 V 9 Ah battery
850 VA
Rated power (480 W)
162-295 V
Input range (230 V)
8 ms
Typical switching time
6-8 h
Recharge time

The CMU-850D 850 VA UPS delivers 850 VA / 480 W and uses microprocessor-based digital control with boost and buck AVR. In the 230 V range the input window is 162-295 V, so the unit can stabilize the output without switching to battery on every voltage dip.

In mains mode the CMU-850D provides a pure sine wave output, and on battery it provides a simulated sine wave, with a typical 8 ms switching time (10 ms maximum). Cold start, automatic restart and a full set of electrical protections make it a practical backup for small equipment. Output outlet types, the LED or LCD display, and the communication and telephone-line protection options are selectable.

Technology features

  • Voltage controlBoost and buck AVR The CMU-850D regulates voltage automatically over a wide input range, giving a steadier output on unstable mains.
  • ControlDigital microprocessor Microprocessor-based control adds auto-sensing frequency and a power-on self test.
  • Battery careSmart battery management Battery temperature compensation helps extend battery life, and three-stage charging shortens the recharge time.
  • ProtectionFull protection set Short-circuit, battery overcharge and overdischarge, overload and surge protections safeguard both the UPS and the load.
  • AvailabilityCold start and auto restart The unit can start on battery with no mains present and restarts automatically once mains power returns.
  • ConnectivityOptional communication An optional RS-232 or USB port enables unattended safety shutdown with system alarm and auto power on and off through a PC, and RJ11 or RJ45 surge protection is also optional.

Phase-tracking output

The CMU-850D automatically tracks the mains phase so that the inverter output has the same phase as the utility voltage. This reduces transfer time and peak surge when the unit switches between mains and battery.

Technical specifications

General
ModelCMU-850D
TypeOffline line interactive
Rated power850 VA / 480 W
CaseMetal
Input
Voltage range (100 / 110 / 120 Vac)80 - 150 Vac
Voltage range (220 / 230 / 240 Vac)162 - 295 / 145 - 295 Vac
Frequency range50 / 60 Hz (auto-sensing)
Output
Voltage (battery mode)100/110/120 or 220/230/240 Vac ± 10%
Frequency (battery mode)50 / 60 Hz ± 1% (auto-sensing)
Waveform (mains mode)Pure sine wave
Waveform (battery mode)Simulated sine wave
Switching time8 ms typical, 10 ms max.
Battery
Model and number12 V / 9 Ah x 1
Recharge time6 - 8 h
Environment and packing
Operating temperature0 °C to 40 °C
Relative humidity5 - 90%
Packing per carton3 pcs
Carton weightNW 18 kg / GW 21 kg
Carton dimensions (L x W x H)45.3 x 38.7 x 24.5 cm
Rear panel
Output outletsSelectable (optional types)
TEL / modem / fax surge protectionOptional
USBOptional
AC input, fuse, AC breakerYes

Integration segments

  1. Home office equipment Keeps a workstation and its peripherals running through short outages, within the 480 W rating.
  2. Small business points of work Backup for compact loads such as small office or counter equipment that must not drop out.
  3. Areas with unstable mains The wide AVR input window stabilizes the output without constantly switching to battery.
  4. Networking and telephony gear The optional TEL, modem, fax, RJ11 and RJ45 surge protection suits communication equipment.

Compact backup with voltage stabilization

The CMU-850D combines boost and buck AVR, cold start and automatic restart in a metal-case 850 VA / 480 W UPS. It gives small loads steady power on unstable mains and a battery-backed supply during outages.

Crown Micro - A trusted global brand

Global backing

Crown Micro: energy engineering with global backing.

  • More than 30 years of international experience in energy solutions
  • Commercial presence in more than 15 countries on four continents
  • Product lines with international certifications
  • Specialized technical support and after-sales engineering
  • Personalized commercial advice for residential and productive projects
  • Solutions across inverters, lithium batteries, frequency drives, panels and kits

Preguntas frecuentes

What is the maximum load the CMU-850D can support?

The CMU-850D is rated at 850 VA / 480 W. The connected load should stay within the 480 W real power rating, and the overload protection guards the unit if it is exceeded.

What input voltage range does the CMU-850D accept?

In the 220 / 230 / 240 Vac range the input window is 162-295 Vac (145-295 Vac is also listed). In the 100 / 110 / 120 Vac range it is 80-150 Vac. Boost and buck AVR stabilizes the output within these windows.

What output waveform does the CMU-850D produce?

The CMU-850D delivers a pure sine wave in mains mode and a simulated sine wave in battery mode. In battery mode the output is 50 / 60 Hz ± 1% with auto-sensing frequency.

How fast does the CMU-850D switch to battery?

The switching time is 8 ms typical and 10 ms maximum. Phase tracking of the mains also helps reduce transfer time and peak surge.

Can the CMU-850D start without mains power?

Yes. The CMU-850D has a cold start function that lets it start on battery with no mains present. It also restarts automatically when mains power is restored.

What battery does the CMU-850D use and how long does it take to recharge?

The unit uses one 12 V / 9 Ah battery. Recharge time is 6-8 h, with three-stage charging and battery temperature compensation. The battery also charges automatically while the UPS is in OFF mode.

Does the CMU-850D offer PC communication?

An RS-232 or USB communication port is optional. It enables unattended safety shutdown with system alarm and auto power on and off through a PC, and RJ11 or RJ45 protection is also available as an option.