Crown Micro VMGI-PRO 3.6-6-SP 3.6-6kW Dual MPPT On-Grid Inverter
SKU: VMGI-PRO 3.6-6-SP
Single-phase on-grid solar inverter with 3.6, 4, 5 and 6 kW ratings, two MPPT trackers, up to 200% PV oversizing, 98.2% maximum efficiency and an IP66 aluminum enclosure.
Tell us about your project and we will recommend the right equipment.
Talk to an advisorKey features
- Nominal output power:3,600 / 4,000 / 5,000 / 6,000 W
- Max. DC power:7,200 / 8,000 / 10,000 / 12,000 W
- MPPT voltage range:70 - 550 V
- MPP trackers / PV strings:2 / 2
- Max. efficiency:98.20%
- Nominal output voltage:L/N/PE, 220 / 230 / 240 VAC
- Protection degree:IP66
- Weight:10 kg
Crown Micro - VMGI-PRO series on-grid inverters
VMGI-PRO 3.6-6-SP On-Grid Inverter 3.6 to 6 kW dual MPPT
The VMGI-PRO 3.6-6-SP is a compact single-phase string inverter that feeds solar energy into the grid at 3.6, 4, 5 or 6 kW. Two independent MPPT trackers and up to 200% PV oversizing let installers fit the array to the roof. It is built for homes and small commercial buildings that need a sealed, silent, grid-tied inverter.
- 3.6 to 6 kW output
- Dual MPPT input
- 98.2% max efficiency
- IP66 aluminum enclosure
- Smart IV scan
- 3.6 - 6 kW
- Nominal AC output power
- 12,000 W
- Max. DC power on the 6 kW model
- 98.2 %
- Max. efficiency
- 2 MPPT
- 18.5 A per tracker
The VMGI-PRO 3.6-6-SP single-phase on-grid inverter covers four ratings: 3.6, 4, 5 and 6 kW of nominal output power. It accepts up to 200% PV oversizing (7,200 to 12,000 W of DC power, depending on the model) on two MPPT trackers with a 70 to 550 V operating range and reaches 98.20% maximum efficiency on every model.
The transformerless aluminum enclosure measures 360 x 358 x 142 mm, weighs 10 kg, is convection cooled and carries an IP66 rating. The inverter includes an integrated DC switch, 10 kA type II surge protection on DC and AC, smart IV curve scanning and several communication options for remote monitoring.
Technology features
- PV inputDual MPPT trackers Two trackers accept 18.5 A each, with one string per tracker and MC4 connectors, over a 70 to 550 V MPPT range.
- EnclosureCompact IP66 design The transformerless aluminum housing is cooled by convection, works from -25 °C to +60 °C and tolerates 0 to 100% humidity.
- Grid outputWide grid compatibility The VMGI-PRO 3.6-6-SP supplies 220 / 230 / 240 VAC at 50 / 60 Hz, with a power factor of 1 (0.8 leading to 0.8 lagging) and current THD below 3%.
- SafetyComplete protection Integrated DC switch, anti-islanding, residual current detection, PV reverse polarity, insulation resistance detection, AC short-circuit, over-current, over-voltage and over-temperature protection.
- DiagnosticsSmart IV curve scanning Built-in IV curve scanning supports PV array diagnostics, and quick arc-fault circuit interruption is available as an option.
- MonitoringFlexible connectivity RS-485, Wi-Fi and wired Ethernet are included, GPRS is optional, and night power consumption stays below 1 W.
Technical specifications
| VMGI-PRO-3.6-SP | 3,600 W nominal; max. 3,960 VA; max. DC power 7,200 W; max. output current 17.5 A; Euro efficiency 97.82% |
|---|---|
| VMGI-PRO-4-SP | 4,000 W nominal; max. 4,400 VA; max. DC power 8,000 W; max. output current 20 A; Euro efficiency 97.85% |
| VMGI-PRO-5-SP | 5,000 W nominal; max. 5,500 VA; max. DC power 10,000 W; max. output current 24 A; Euro efficiency 97.90% |
| VMGI-PRO-6-SP | 6,000 W nominal; max. 6,600 VA; max. DC power 12,000 W; max. output current 28.7 A; Euro efficiency 97.92% |
| Max. efficiency (all models) | 98.20% |
| Max. DC voltage | 600 V |
|---|---|
| MPPT voltage range | 70 to 550 V |
| Rated input voltage | 360 V |
| Start-up voltage | 70 V |
| Max. input current | 18.5 A x 2 |
| Max. short-circuit current | 25 A x 2 |
| MPP trackers / PV strings | 2 / 2 |
| Input connector type | MC4 |
| Nominal output voltage | L/N/PE, 220 / 230 / 240 VAC |
|---|---|
| Grid voltage range | 180 to 276 VAC (according to local grid standard) |
| Nominal output frequency | 50 / 60 Hz |
| Grid frequency range | 45 to 55 Hz / 54 to 66 Hz (according to local grid standard) |
| Output power factor | 1 (0.8 leading to 0.8 lagging) |
| Output current THD | < 3% |
| PV reverse polarity protection | Yes |
|---|---|
| PV insulation resistance detection | Yes |
| AC short-circuit protection | Yes |
| AC over-current protection | Yes |
| AC over-voltage protection | Yes |
| Anti-islanding protection | Yes |
| Residual current detection | Yes |
| Over-temperature protection | Yes |
| Integrated DC switch | Yes |
| Surge protection | 10 kA type II varistor, DC and AC |
| Smart IV curve scanning | Yes |
| Quick arc-fault circuit interruption | Optional |
| Dimensions (W x H x D) | 360 x 358 x 142 mm |
|---|---|
| Weight | 10 kg |
| Protection degree | IP66 |
| Enclosure material | Aluminum |
| Topology | Transformerless |
| Cooling | Convection |
| Ambient temperature | -25 °C to +60 °C |
| Humidity range | 0 to 100% |
| Communication | RS-485 / Wi-Fi / Ethernet / GPRS (optional) |
| Night power consumption | < 1 W |
| Max. operating altitude | 4,000 m |
| EMC | EN IEC 61000-6-1, EN IEC 61000-6-2, EN IEC 61000-6-3, EN IEC 61000-6-4, EN IEC 61000-3-2, EN 61000-3-3, EN IEC 61000-3-11, EN 61000-3-12, EN 62920 |
|---|---|
| Safety | IEC/EN 62109-1, IEC/EN 62109-2, IEC 61683 |
| Grid connection | IEC 61727, IEC 62116, VDE-AR-N 4105, IEC 63027 |
Integration segments
- Residential rooftop systems Single-phase homes can feed surplus solar energy into the grid with a 3.6 to 6 kW inverter.
- Small commercial buildings Shops, offices and workshops can use the 4, 5 and 6 kW ratings with PV arrays sized up to 200% of the AC rating.
- Arrays with two string groups Two independent MPPT trackers, each with one string, let installers connect two separate PV strings to a single inverter.
- Outdoor and demanding sites The IP66 aluminum enclosure, the -25 °C to +60 °C temperature range and operation up to 4,000 m suit exposed installations.
Global backing
Crown Micro: energy engineering with global backing.
- More than 30 years of international experience in energy solutions
- Commercial presence in more than 15 countries on four continents
- Product lines with international certifications
- Specialized technical support and after-sales engineering
- Personalized commercial advice for residential and productive projects
Frequently asked questions
What power ratings does the VMGI-PRO 3.6-6-SP cover?
The series covers four models: VMGI-PRO-3.6-SP (3,600 W), VMGI-PRO-4-SP (4,000 W), VMGI-PRO-5-SP (5,000 W) and VMGI-PRO-6-SP (6,000 W) of nominal output power. Maximum output power is 3,960, 4,400, 5,500 and 6,600 VA respectively.
How much PV power can I connect?
The inverter accepts up to 200% PV oversizing. Maximum DC power is 7,200 W on the 3.6 kW model, 8,000 W on the 4 kW, 10,000 W on the 5 kW and 12,000 W on the 6 kW model. Open-circuit PV voltage must not exceed 600 VDC at the lowest site temperature.
How many MPPT trackers and strings does it have?
The VMGI-PRO 3.6-6-SP has two MPPT trackers and two PV strings, one per tracker. Each tracker accepts a maximum input current of 18.5 A and a short-circuit current of 25 A, and the inputs use MC4 connectors.
Which grid voltages and frequencies are supported?
Nominal output is L/N/PE at 220 / 230 / 240 VAC and 50 / 60 Hz. The grid voltage range is 180 to 276 VAC and the frequency range is 45 to 55 Hz or 54 to 66 Hz, according to the local grid standard.
Can it be installed outdoors?
The inverter has an IP66 protection degree and an aluminum enclosure. It is rated for ambient temperatures from -25 °C to +60 °C, humidity of 0 to 100% and a maximum operating altitude of 4,000 m. It is cooled by convection, so it has no fan.
How can the inverter be monitored?
It provides RS-485, Wi-Fi and wired Ethernet communication, with GPRS available as an option. Night power consumption is below 1 W.
Which protections and standards does it include?
It includes an integrated DC switch, anti-islanding, residual current detection, PV reverse polarity protection and AC short-circuit, over-current, over-voltage and over-temperature protection. Surge protection is a 10 kA type II varistor on DC and AC, and quick arc-fault circuit interruption is optional. Listed standards include IEC/EN 62109-1 and 62109-2, IEC 61727, IEC 62116, VDE-AR-N 4105 and IEC 63027.